Research Article

FEM Analysis of Mandibular Prosthetic Overdenture Supported by Dental Implants: Evaluation of Different Retention Methods

Table 3

Maximum stresses for component [MPa] (Model A).

LoadInsertSheathAbutmentImplantCortical
bone
Midollar
bone

COMP.98,62150,72499,88176,5864,224,91
C. 45°271,34346,864180,8552,93142,687,73
F. 90°345,02483,045186,8633,07161,179,16
T. 45°258,55333,574234,1569,81157,477,68
TRAZ.71,09152,57499,89177,1265,174,95