Research Article

Registration and Summation of Respiratory-Gated or Breath-Hold PET Images Based on Deformation Estimation of Lung from CT Image

Table 3

Evaluation of estimated motion angle in phantom experiment.

Respi. phasePrevious RSM [degree]Proposed RSM [degree]
AxialCoronalSagittalAxialCoronal Sagittal

213.06.96.61.72.22.5
312.76.37.02.32.21.9
417.110.29.62.12.02.3
518.08.711.72.71.71.7
616.58.310.12.52.22.5
718.09.310.22.42.32.3
814.68.39.11.92.22.4
913.37.46.12.02.62.2
1011.56.15.72.22.61.9