Research Article
An Improved Sliding Window Area Method for T Wave Detection
Table 4
Results of T wave detection in the European ST-T database.
| Detection | Channel | Method | Se (%) | P+ (%) | F1 (%) | Error mean ± SD (ms) |
| Onset | First | Traditional SWA [32] | 41.02 | 41.02 | 41.02 | 19.52 ± 31.89 | Improved SWA | 84.13 | 84.13 | 84.13 | −7.87 ± 44.22 | Second | Traditional SWA [32] | 44.33 | 44.32 | 44.33 | −36.27 ± 43.29 | Improved SWA | 87.62 | 87.61 | 87.62 | −15.20 ± 33.54 |