BMSCs viability (%) after LIPUS stimulation with 3 min.

Voltage (V)Frequency (MHz)
00.60.811.2

5100100.57 ± 6.52103.40 ± 5.91105.17 ± 7.17100.92 ± 8.18
Confidence intervals (%)[100,100][97.52,103.62][100.63,106.16][101.81,108.53][97.09,104.74]
values0.6990.0140.0030.619

6100101.15 ± 16.08104.81 ± 12.95107.72 ± 14.07100.71 ± 13.13
Confidence intervals (%)[100,100][93.62,108.68][98.75,110.87][101.13,114.30][94.57,106.86]
values0.7510.1050.0190.81

7100102.8 ± 10.92102.84 ± 10.81103.94 ± 6.54100.59 ± 7.15
Confidence intervals (%)[100,100][97.69,107.91][97.78,107.90][100.88,106.10][97.24,103.94]
values0.2590.2480.010.715

8100101.57 ± 7.73102.46 ± 10.56102.34 ± 12.14101.48 ± 9.82
Confidence intervals (%)[100,100][97.95,105.20][97.51,107.40][96.66,108.02][96.88,106.07]
values0.3680.3050.3940.505

Data presented as mean ± SD, n = 20 (, ).