Research Article

Low-Dose CT Image Denoising with Improving WGAN and Hybrid Loss Function

Table 8

Quantitative results for Figure 13 (the results of MDLCT dataset) utilizing different loss function.

Quantitative measurementsAdversarial lossPerceptual lossSharpness lossStructural similarity lossHybrid loss

PSNR/dB24.6626.8626.5725.6028.8961
SSIM0.84850.75520.83010.80580.8596
FSIM0.94850.94460.96350.96650.9762