Figure 6

Steps to generate the simulated training set. (a) 50 single-period pulse waveforms were extracted from pulse wave signals of the 50 selected cases by TSA. (b) 1000 single-period pulse waveforms were generated by stretching or compressing the original single-period pulse waveform to make its length equal to . (c) 60 single-period pulse waveforms were generated by stretching or compressing the corresponding single-period pulse waveform generated in (b) to make its length equal to separately. Only the waveforms of diastole were stretched or compressed in this step. The pulse wave series of each training sample were subsequently obtained by connecting the 60 single-period pulse waveforms end to end.
(a)
(b)
(c)