Research Article
Differential Diagnosis Model of Hypocellular Myelodysplastic Syndrome and Aplastic Anemia Based on the Medical Big Data Platform
Table 6
The comparison of the training set evaluation index.
| Aspects | Index | Logistic | Decision tree | BP neural network | SVM |
| Authenticity | Sensitivity (%) | 68.75 | 98.96 | 84.38 | 69.79 | Specificity (%) | 78.76 | 92.04 | 78.76 | 82.30 | Youden index | 0.48 | 0.91 | 0.63 | 0.52 | +LR | 3.24 | 12.42 | 3.97 | 3.94 | −LR | 0.40 | 0.01 | 0.20 | 0.37 | AUC (95% CI) | 0.74 (0.67, 0.80) | 0.96 (0.92, 0.98) | 0.82 (0.76, 0.87) | 0.76 (0.70, 0.82) |
| Reliability | Accuracy (%) | 74.16 | 95.22 | 81.34 | 76.56 | Kappa | 0.48 | 0.90 | 0.63 | 0.53 |
| Benefit | +PV (%) | 73.33 | 91.35 | 77.14 | 77.01 | −PV (%) | 74.79 | 99.05 | 85.58 | 76.23 |
|
|