Research Article
Effect of EOG Signal Filtering on the Removal of Ocular Artifacts and EEG-Based Brain-Computer Interface: A Comprehensive Study
Table 5
Signal-to-artifact ratio for contaminated EEG, corrected EEG, and gain (mean of all EEG channels and mean of all simulated subjects).
| Low-pass EOG filter (Hz) | SAR before artifact removal | Simple | Adaptive filtering | Hybrid methods | Regression (mean ± SD) | LMS (mean ± SD) | RLS (mean ± SD) | REGICA (mean ± SD) | AIR (mean ± SD) | After | Gain | After | Gain | After | Gain | After | Gain | After | Gain |
| 4 | 78.54 | 112.7 | 1.44 | 116.3 | 1.49 | 120.7 | 1.54 | 123.2 | 1.57 | 124.0 | 1.58 | 5 | 114.5 | 1.46 | 118.3 | 1.51 | 123.9 | 1.58 | 127.3 | 1.63 | 128.3 | 1.64 | 6 | 115.4 | 1.47 | 119.2 | 1.52 | 125.7 | 1.60 | 129.8 | 1.66 | 130.8 | 1.67 | 7 | 115.7 | 1.47 | 119.2 | 1.52 | 126.2 | 1.61 | 130.7 | 1.67 | 131.8 | 1.68 | 8 | 115.6 | 1.47 | 118.9 | 1.52 | 125.9 | 1.61 | 130.7 | 1.67 | 131.7 | 1.68 | 9 | 115.4 | 1.47 | 118.5 | 1.51 | 125.4 | 1.60 | 130.2 | 1.66 | 131.2 | 1.68 | 10 | 115.2 | 1.47 | 118.2 | 1.51 | 124.9 | 1.60 | 129.7 | 1.66 | 130.7 | 1.67 | 12 | 114.9 | 1.46 | 117.7 | 1.50 | 124.2 | 1.59 | 128.9 | 1.65 | 129.9 | 1.66 | 15 | 114.7 | 1.46 | 117.5 | 1.50 | 123.7 | 1.58 | 128.4 | 1.64 | 129.3 | 1.65 | 20 | 114.5 | 1.46 | 117.3 | 1.50 | 123.4 | 1.58 | 128.0 | 1.63 | 128.9 | 1.65 | 25 | 114.5 | 1.46 | 117.2 | 1.50 | 123.3 | 1.57 | 127.8 | 1.63 | 128.7 | 1.64 | 35 | 114.4 | 1.46 | 117.1 | 1.50 | 123.1 | 1.57 | 127.7 | 1.63 | 128.6 | 1.64 | Unfiltered | 114.2 | 1.46 | 116.9 | 1.49 | 122.8 | 1.57 | 127.2 | 1.62 | 128.1 | 1.64 |
|
|