Research Article

Application of Supply-Demand-Based Optimization for Parameter Extraction of Solar Photovoltaic Models

Table 14

Calculated results for the STP6-120/36 module by SDO.

ItemVL (V)IL measured (A)SDMDDM
IL calculated (A)IAE (A)IL calculated (A)IAE (A)

119.21000.00000.001164340.001164340.001156000.00115600
217.65003.83003.832282330.002282333.832284600.00228460
317.41004.29004.273929110.016070894.273931140.01606886
417.25004.56004.546289870.013710134.546291620.01370838
517.10004.79004.785833020.004166984.785834430.00416557
616.90005.07005.081933890.011933895.081934810.01193481
716.76005.27005.273765160.003765165.273765710.00376571
816.34005.75005.776813810.026813815.776813350.02681335
916.08006.00006.037492390.037492396.037491460.03749146
1015.71006.36006.348727430.011272576.348726100.01127390
1115.39006.58006.567929370.012070636.567927980.01207202
1214.93006.83006.814860110.015139896.814859010.01514099
1314.58006.97006.958449050.011550956.958448390.01155161
1414.17007.10007.088137310.011862697.088137320.01186268
1513.59007.23007.217761040.012238967.217762040.01223796
1613.16007.29007.284130030.005869977.284131710.00586829
1712.74007.34007.331483140.008516867.331485380.00851462
1812.36007.37007.363264820.006735187.363267460.00673254
1911.81007.38007.395873150.015873157.395876200.01587620
2011.17007.41007.420265000.010265007.420268280.01026828
2110.32007.44007.439092230.000907777.439095490.00090451
229.74007.42007.446714970.026714977.446718050.02671805
239.06007.45007.452537550.002537557.452540320.00254032
240.00007.48007.470981780.009018227.470977310.00902269
Sum of IAE0.277974280.27797339