Research Article

Application of Supply-Demand-Based Optimization for Parameter Extraction of Solar Photovoltaic Models

Table 5

Calculated results for the RTC France solar cell by SDO.

ItemVL (V)IL measured (A)SDMDDM
IL calculated (A)IAE (A)IL calculated (A)IAE (A)

1−0.20570.76400.764087650.000087650.763978650.00002135
2−0.12910.76200.762662640.000662640.762601030.00060103
3−0.05880.76050.761354730.000854730.761336410.00083641
40.00570.76050.760154240.000345760.760175020.00032498
50.06460.76000.759055930.000944070.759110900.00088910
60.11850.75900.758043340.000956660.758126160.00087384
70.16780.75700.757091590.000091590.757192930.00019293
80.21320.75700.756142070.000857930.756248790.00075121
90.25450.75550.755087320.000412680.755181420.00031858
100.29240.75400.753664470.000335530.753724780.00027522
110.32690.75050.751388060.000888060.751395260.00089526
120.35850.74650.747348340.000848340.747292100.00079210
130.38730.73850.740096880.001596880.739984630.00148463
140.41370.72800.727396780.000603220.727257090.00074291
150.43730.70650.706953280.000453280.706829360.00032936
160.45900.67550.675294920.000205080.675227130.00027287
170.47840.63200.630884330.001115670.630888810.00111119
180.49600.57300.572082070.000917930.572144590.00085541
190.51190.49900.499491670.000491670.499575880.00057588
200.52650.41300.413493640.000493640.413560390.00056039
210.53980.31650.317219500.000719500.317243340.00074334
220.55210.21200.212103170.000103170.212079880.00007988
230.56330.10350.102721360.000778640.102668200.00083180
240.5736−0.0100−0.009248780.00075122−0.009300400.00069960
250.5833−0.1230−0.124381360.00138136−0.124391130.00139113
260.5900−0.2100−0.209193080.00080692−0.209144190.00085581
Sum of IAE0.017703810.01730620