Research Article

Solving the Complexity Problem in the Electronics Production Process by Reducing the Sensitivity of Transmission Line Characteristics to Their Parameter Variations

Table 3

Comparison of computed C (pF/m) and L (nH/m) entries for 3 strips of various positions in a two-layer dielectric medium.


ResultsC11–C21–C31C22–C32C33

Result [27]142.121.70.993.518.188.0

Our result143.619.80.988.617.783.1

Error, %1.1–8.80–5.2–2.2–5.6

ResultsL11L21L31L22L32L33

Result [27]277.787.836.8328.6115.8338.0

Our result279.487.636.5330.7115.5339.0

Error, %0.6–0.2–0.80.6–0.30.3