Research Article

Harmonic Modeling and Experimental Validation of the Converters of DFIG-Based Wind Generation System

Table 1

Detailed parameters of the DFIG simulation platform.

ParametersValues

LCL filter (L1)2 mH
LCL filter (L2)1 mH
LCL filter (C)18 μF
Asynchronous motor (Lr)0.404 mH
Asynchronous motor (Rr)0.0079 Ω
Asynchronous motor (Ls)0.08 mH
Asynchronous motor (Rs)0.0025 Ω
Asynchronous motor (Lm)4.4 mH
sslip−0.2