Research Article
Harmonic Modeling and Experimental Validation of the Converters of DFIG-Based Wind Generation System
Table 1
Detailed parameters of the DFIG simulation platform.
| Parameters | Values |
| LCL filter (L1) | 2 mH | LCL filter (L2) | 1 mH | LCL filter (C) | 18 μF | Asynchronous motor (Lr) | 0.404 mH | Asynchronous motor (Rr) | 0.0079 Ω | Asynchronous motor (Ls) | 0.08 mH | Asynchronous motor (Rs) | 0.0025 Ω | Asynchronous motor (Lm) | 4.4 mH | sslip | −0.2 |
|
|