| Item | Load level—light 50% | Method | CSA [16] | IHA [17] | FPA [18] | ABC [19] | MGABC [30] | SOSc | SQI-SOSc | SOS | SQI-SOS |
| Locations (kVArs) | 32 (0) | 39 (1200) | 32 (0) | 32 (500) | 33 (300) | 96 (561.52) | 50 (977.53) | 42 (400) | 32 (850) | 39 (1100) | 43 (0) | 40 (1100) | 35 (0) | 35 (750) | 107 (636.82) | 96 (548.25) | 111 (750) | 80 (800) | 40 (0) | 70 (900) | 70 (750) | 40 (0) | 45 (300) | 80 (807.44) | 32 (899.34) | 80 (800) | 74 (750) | 70 (350) | 74 (0) | 74 (1100) | 50 (0) | 46 (150) | 50 (982.00) | 80 (811.47) | 74 (750) | 111 (800) | 74 (500) | 86 (0) | 89 (500) | 70 (0) | 49 (900) | 74 (753.84) | 107 (626.67) | 96 (550) | 96 (550) | 86 (450) | 91 (600) | 104 (0) | 73 (750) | 54 (450) | 42 (393.18) | 42 (392.52) | 107 (600) | 107 (550) | 108 (0) | 107 (0) | 109 (0) | 79 (500) | 71 (750) | 32 (904.33) | 111 (733.85) | 50 (950) | 50 (1000) | 118 (1000) | 109 (0) | 112 (0) | 105 (300) | 76 (150) | 111 (753.84) | 74 (751.84) | 33 (750) | 42 (400) | | 118 (1000) | 118 (1000) | 106 (0) | 86 (750) | | | | | | | | 109 (0) | 94 (300) | | | | | | | | 110 (950) | 101 (750) | | | | | | | | | 110 (600) | | | | | | | | | 111 (450) | | | | | | | | | 114 (150) | | | | | | | | | 115 (150) | | | | | Total kVAr | 3400 | 3700 | 3350 | 3900 | 6900 | 5777.11 | 5741.51 | 5550 | 5700 | Total kVAr demand | 8520.55 | | | | | | | | |
| Load level—medium 75% | Locations (kVArs) | 32 (900) | 39 (1500) | 32 (0) | 32 (0) | 33 (600) | 96 (804.70) | 50 (1499.95) | 42 (550) | 32 (1050) | 39 (1500) | 43 (0) | 40 (1500) | 35 (800) | 35 (1200) | 107 (903.13) | 96 (820.33) | 111 (1100) | 80 (1100) | 40 (0) | 70 (900) | 70 (750) | 40 (1200) | 45 (300) | 80 (1107.43) | 32 (1137.43) | 80 (1100) | 74 (1150) | 70 (600) | 74 (600) | 74 (600) | 50 (450) | 46 (150) | 50 (1497.64) | 80 (1087.39) | 74 (1150) | 111 (1150) | 74 (750) | 86 (0) | 89 (1500) | 70 (550) | 49 (1350) | 74 (1146.86) | 107 (904.62) | 96 (800) | 96 (800) | 86 (700) | 91 (1500) | 104 (0) | 73 (750) | 54 (750) | 42 (553.04) | 42 (556.16) | 107 (950) | 107 (900) | 108 (750) | 107 (0) | 109 (0) | 79 (850) | 71 (1050) | 32 (1122.45) | 111 (1132.41) | 50 (1500) | 50 (1500) | 118 (1100) | 109 (0) | 112 (0) | 105 (0) | 76 (300) | 111 (1133.50) | 74 (1145.73) | 33 (1000) | 42 (600) | | 118 (1200) | 118 (1000) | 106 (0) | 86 (1050) | | | | | | | | 109 (800) | 94 (450) | | | | | | | | 110 (1000) | 101 (1200) | | | | | | | | | 110 (900) | | | | | | | | | 111 (600) | | | | | | | | | 114 (150) | | | | | | | | | 115 (150) | | | | | Total kVAr | 6300 | 5700 | 5350 | 6400 | 10200 | 8268.79 | 8284.06 | 8150 | 8250 | Total kVAr demand | 12780.83 | | | | | | | | |
| Load level—full 100% | Locations (kVArs) | 32 (1500) | 39 (1500) | 32 (1500) | 32 (850) | 33 (900) | 96 (804.85) | 50 (1499.95) | 42 (550) | 32 (1050) | 39 (1500) | 43 (1000) | 40 (1500) | 35 (1050) | 35 (1500) | 107 (903.63) | 96 (820.46) | 111 (1400) | 80 (1100) | 40 (550) | 70 (1000) | 70 (850) | 40 (1300) | 45 (450) | 80 (1107.66) | 32 (1137.43) | 80 (1100) | 74 (1400) | 70 (950) | 74 (1000) | 74 (1100) | 50 (800) | 46 (450) | 50 (1499.53) | 80 (1087.45) | 74 (1400) | 111 (1450) | 74 (750) | 86 (900) | 89 (1500) | 70 (550) | 49 (1500) | 74 (1395.53) | 107 (904.64) | 96 (800) | 96 (800) | 86 (1050) | 91 (1500) | 104 (500) | 73 (1300) | 54 (1050) | 42 (553.16) | 42 (556.20) | 107 (950) | 107 (900) | 108 (1500) | 107 (850) | 109 (900) | 79 (1200) | 71 (1200) | 32 (1122.81) | 111 (1435.61) | 50 (1500) | 50 (1500) | 118 (1200) | 109 (850) | 112 (250) | 105 (700) | 76 (450) | 111 (1436.75) | 74 (1408.13) | 33 (1000) | 42 (600) | | 118 (1200) | 118 (1150) | 106 (250) | 86 (1350) | | | | | | | | 109 (800) | 94 (750) | | | | | | | | 110 (1200) | 101 (1500) | | | | | | | | | 110 (1350) | | | | | | | | | 111 (750) | | | | | | | | | 114 (150) | | | | | | | | | 115 (150) | | | | | Total kVAr | 9000 | 9800 | 9250 | 10000 | 13500 | 8823.94 | 8849.91 | 8700 | 8800 | Total kVAr demand | | | | | 17041.1 | | | | |
| Fixed capacitors | SOS | (42, 400); (111, 750); (80, 800); (74, 750); (96, 550); (107, 600); (50, 950); (33, 750) | SQI-SOS | (32, 850); (80, 800); (74, 750); (111, 800); (96, 550); (107, 550); (50, 1000); (42, 400) | Switched capacitors | SOS | (42, 150); (111, 650); (80, 300); (74, 650); (96, 250); (107, 350); (50, 550); (33, 250) | SQI-SOS | (32, 200); (80, 300); (74, 650); (111, 650); (96, 250); (107, 350); (50, 500); (42, 200) |
|
|