Research Article

Interference Analysis of Metal Conductors for Target-Resonance-Based Detection Method

Table 4

The maximum detection distances when different barriers are placed 2 cm away from the transmitter.

Metal plateMetal grid
25 mm  25 mm50 mm  50 mm100 mm  100 mm

100% shielded13.5 cm19.5 cm23 cm
75% shielded20.0 cm21.5 cm23.5 cm25.5 cm
50% shielded25.5 cm26.5 cm27.5 cm28 cm
25% shielded28.0 cm29.0 cm29.5 cm29.5 cm