Research Article

Vibration Reliability Analysis of Drum Brake Using the Artificial Neural Network and Important Sampling Method

Table 8

The mean and standard deviation of the design parameters.

Design parametersMeanStandard deviationDistributionUnits

x1 (Dd)7330366.5Normalkg/m3
x2 (Ed)1.48 E + 57400NormalMPa
x3 (Pd)0.310.0155Normal
x4 (Ds)2540127Normalkg/m3
x5 (Es)1.0 E + 55000NormalMPa
x6 (Ps)0.250.0125Normal
x7 (Dp)7100355Normalkg/m3
x8 (Ep)7.252 E + 43626NormalMPa
x9 (Pp)0.320.016Normal