Research Article

Modified Whale Optimization Algorithm for Solar Cell and PV Module Parameter Identification

Table 12

The optimal extracted parameters for SM55 based on MWOA at various temperatures with irradiance of 1000 .

ParameterTemperature
25°C40°C50°C70°C

SDM
(A)2.6708051712.6781365782.6922265842.692391664
2.99498E − 067.45505E − 061.82816E − 058.72477E − 05
1.0635557111.1099298411.1513490181.126145392
468.8521810425.9939767291.6453129366.3672871
1.8349541181.7590789251.7145086111.726804626
RMSE2.63628E − 031.823996E − 031.825667E − 037.77905E − 04
DDM
(A)2.6713980292.6796662302.6896716082.692165113
2.11052E − 064.11310E − 066.53862E − 064.07806E − 05
5.16008E − 059.13747E − 057.44782E − 055.01099E − 05
1.0832331931.1395569341.1708332511.126314671
465.8813651409.7291090350.2016170372.8377988
1.7908069241.6839902941.5968897391.687289644
43.4591033142.3838041271.787270097
RMSE2.026022E − 031.434158E − 031.691410E − 037.86324E − 03