Research Article
Optimal Control Strategy of Platform Load Oriented to Network and Load Cooperation
Table 9
Line parameters of the IEEE 33-node system.
| Branch circuit | Branch impedance | Ground capacitance |
| 0-1 | 0.0922 + j0.047 | 0.0412 | 1-2 | 0.01938 + j0.05917 | 0.0528 | 2-3 | 0.04699 + j0.19797 | 0.0438 | 3-4 | 0.05811 + j0.17632 | 0.0374 | 4-5 | 0.05403 + j0.22304 | 0.0492 | 5-6 | 0.05695 + j0.17388 | 0.0340 | 6-7 | 0.06701 + j0.17103 | 0.0346 | 7-8 | 0.00000 + j0.17615 | 0.0000 | 7-9 | 0.00000 + j0.11001 | 0.0000 | 8-9 | 1.0440 + j0.7400 | 0.0000 | 9-10 | 0.1966 + j00650 | 0.0000 | 10-11 | 0.3744 + j0.1238 | 0.0000 | 11-12 | 1.4680 + j1.550 | 0.0000 | 12-13 | 0.5416 + j0.7129 | 0.0000 | 13-14 | 0.5910 + j0.5620 | 0.0000 | 14-15 | 0.7463 + j0.5450 | 0.0000 | 15-16 | 1.2890 + j1.7210 | 0.0000 | 1-18 | 0.09498 + j0.1989 | 0.0000 | 18-19 | 0.12291 + j0.25581 | 0.0000 | 19-20 | 0.06615 + j0.13027 | 0.0000 | 20-21 | 0.12711 + j0.27038 | 0.0000 | 2-22 | 0.08205 + j0.19207 | 0.0000 | 22-23 | 0.22092 + j0.19988 | 0.0000 | 23-24 | 0.17093 + j0.34802 | 0.0000 | 5-25 | 0.2030 + j0.1034 | 0.0000 | 25-26 | 0.2842 + j0.1447 | 0.0000 | 26-27 | 1.0590 + j0.9337 | 0.0000 | 27-28 | 0.8042 + j0.7006 | 0.0000 | 28-29 | 0.5075 + j0.2585 | 0.0000 | 29-30 | 0.9744 + 0.9630 | 0.0000 | 30-31 | 0.3105 + j0.3619 | 0.0000 | 31-32 | 0.3410 + j0.5362 | 0.0000 |
|
|