Aortic Balloon Valvuloplasty Prior to Orthotopic Liver Transplantation: A Novel Approach to Aortic Stenosis and End-Stage Liver Disease

Table 1

Patient and procedural characteristics before and after valvuloplasty.

Patient 1Patient 2Patient 3Patient 4

Age, y/sex58/female63/male56/male58/male
DiagnosisPrimary biliary CirrhosisHemochromatosisNonalcoholic steatohepatitisHepatitis C
Platelet count1011012438
MELD score38281636
BNP8014193354

Hemodynamic data  Pre  PostPrePost  Pre  Post  Pre  Post

Gradients, mean (mmHg)  37  284516  35  25  45  25
Aortic valve area (cm2)  0.8  1.00.61.2  1.0  1.1  0.7  1.1
Ejection fraction  60%  64%60%70%  65%  70%  68%  65%

Procedure data
 Time to transplant38 hrs4 mo6 hrs20 hrs
 Balloon size23 mm, CRISTAL23 mm, CRISTAL23 mm, Z-MED II
 Sheath size8 French10 French10 French12 French
 Sheath removalSurgical, time of transplantSurgical, 48 hrs after transplantTime of transplant
 Follow-up, mo/outcomes24 mo, alive, s/p AVR10 mo, alive24 mo, alive, s/p AVR Deceased, perivalvular abscess

Estimated by transthoracic echocardiographic measurement; continuity equation unrecorded.