Case Reports in Dentistry

Case Reports in Dentistry / 2015 / Article

Case Report | Open Access

Volume 2015 |Article ID 750313 | 4 pages | https://doi.org/10.1155/2015/750313

Endocrown with Leucite-Reinforced Ceramic: Case of Restoration of Endodontically Treated Teeth

Academic Editor: Wafa El-Badrawy
Received08 Jun 2015
Accepted01 Oct 2015
Published18 Oct 2015

Abstract

A common problem encountered by dentists is the restorative treatment of nonvital teeth. When the pulp chamber presents appropriate conditions for retention, the endocrown is indicated. This monolithic, ceramic adhesive restoration is singularly used yet warrants wider recognition and use. The endocrown allows preservation of the tooth structure and is minimally invasive. Currently, this treatment option, of a core buildup and full coverage restoration, reduces tooth structure excessively. This treatment presents not only functional limitations but also aesthetic concerns. Recently, the VITA-PM9 system, a leucite-reinforced glass ceramic, has been increasingly used in a variety of clinical situations due to its satisfactory physical-mechanical and aesthetic properties. Therefore, the present study describes a case of surgical restoration of a nonvital tooth using the endocrown technique and the VITA-PM9.

1. Introduction

The restoration of endodontically treated teeth has long been a challenge for dentists. These teeth often have little remaining crown, and the biomechanical principles of retention and resistance are compromised [1]. One treatment option for previously treated teeth is the placement of intracanal posts to retain and anchor the restoration material [2]. However, many clinicians are unclear on the criteria for utilizing cementation of intraradicular posts as many variables must be considered [3]. In addition, placement of the intracanal post risks root perforation and thinning of the root canal walls as a result of overpreparation [4]. These cases often require preparation of the remaining or entire crown in order to stabilize the remaining tooth structure and replace the lost material. However, a simpler, faster, and more conservative alternative is needed.

In order to devise a conservative treatment option for endodontically treated teeth, Bindl and Mörmann proposed the restoration of nonvital teeth using the pulp chamber for support of the definitive onlay restoration. This all-ceramic restoration technique, called the endocrown, was first described using the CEREC system [5]; however, other systems may be employed in this particular restoration [6].

Recently, the VITA-PM9 system (Vident, Brea, CA, USA) was released, which is a pressed ceramic that uses a microparticulate coating. The system employs thin feldspathic ceramic, which provides excellent resistance and polish. The system is commercially available in tablet form and is recommended for use in anterior crowns, veneers, inlays, onlays, and partial crowns.

The present case report describes an aesthetic and conservative posterior endocrown restoration of a nonvital tooth using VITA-PM9.

2. Case Presentation

A 23-year-old female patient presented for evaluation at the Department of Restorative Dentistry, Bauru School of Dentistry, University of São Paulo, Brazil. Radiographic and clinical examinations were performed initially (Figures 1 and 2), and a provisional restoration of a nonvital molar tooth (46) was identified. After removing the provisional restoration, an endocrown restoration was recommended due to the amount of remaining tooth structure (Figure 3).

Shade selection was then performed. The surrounding teeth were restored with composite resin in a single section and covered with a rubber dam. The pulp chamber was exposed and the occlusal surface was prepared with a diamond bur (Mani, Japan) (Figure 4). The entire cavity and interocclusal space were evaluated. An impression was obtained using retraction cords (Pro Retract 0000, FGM; Joinville, SC, Brazil) and vinyl polysiloxane (Express XT, 3M/ESPE; Seefeld, Germany). The heavy-bodied and light-bodied impression materials were used.

A provisional restoration was constructed from a bis-acryl resin (ProTemp 4, 3M ESPE; Seefeld, Germany).

The endocrown was fabricated with an injected leucite-reinforced ceramic (VITA-PM9; Bad Säckingen, Germany) using the heat press technique (Figure 5). The VITA AKZENT Plus (Bad Säckingen, Germany) was custom-applied to enhance the shading and optical characteristics of the restoration (Figure 6).

The internal surface was etched with hydrofluoric acid (Porcelain Etchant, FGM Produtos Odontológicos; Joinville, Santa Catarina, Brazil) for 60 s, rinsed with running water, and dried with an air syringe. The restoration was treated with Prosil, which is a silane coupling agent (FGM, Joinville, Santa Catarina, Brazil) according to the manufacturer’s instructions. One coat of hydrophobic resin (Adper ScotchBond Multi-Purpose, 3M/ESPE, Seefeld, Germany) was applied and light-cured for 10 s.

Rubber dam was used to achieve proper isolation and then hydrophobic agent was applied onto the tooth surface (Figure 7). The endocrown restoration was bonded with a dual curable resin-based luting agent (Rely X ARC, 3M/ESPE; Seefeld, Germany). The excess cement was removed, and the restoration was light polymerized using an LED-curing unit (Radii-Cal, SDI, Victoria, Australia) for 40 seconds per margin. The restoration was examined for any occlusal interference using ceramic finishing instruments (Jota AG Rotatory Instruments, Rüthi, Switzerland). The final restoration is shown in Figures 8(a) and 8(b).

3. Discussion

The choice to reconstruct or restore nonvital teeth is a difficult decision for dental professionals. Aspects such as planning, selection of the restorative system, and the specific cavity preparation should be carefully considered [1].

Endodontic crowns, known as endocrowns, were initially proposed in 1999 by Bindl and Mörmann, who employed the CEREC system (Sirona) [5]. The restoration was constructed using computer-aided design/manufacturing (CAD/CAM) and bonded to the preparation with reduced macroretention. However, other systems may also be employed, and recently Lander and Dietschi used the Empress II system to restore two molars with the endocrown technique [7]. In the present report, the VITA-PM9 system was employed. This dental ceramic system, newly introduced to the market, may show long-term efficacy similar to other VITA systems [8, 9]. According to the manufacturer, the VITA-PM9 is a pressed ceramic in a fine feldspathic composition, which produces excellent aesthetic results and polish. The system is also available in a variety of colors and translucencies and can be used in a wide range of cases including inlays, veneers, anterior crowns, onlays, and partial crowns, as in the present study.

The VITA AKZENT Plus uses glazing and masking technique and glazing agents to enable shade modification by the clinician. Fluorescent masking of the stains ensures excellent shading and can be used to apply natural surface effects without requiring a ceramic layer. This monolithic ceramic restoration, according to Schultheis et al., appears to be a reliable alternative for posterior load-bearing teeth, whereas a bilayer configuration is more susceptible to low load fracture failure [10].

The quantity and quality of the coronal structure are crucial in this clinical scenario [4]. Cast metal cores or intracanal posts are frequently employed clinically. Goto et al. observed that metallic cores can generate a wedge effect on the root and require a longer laboratory phase [11]. By contrast, the adhesion of prefabricated posts has limited long-term stability [12], making this procedure effective only in selected cases. Thus, other therapeutic alternatives should be considered. When the pulp chamber retention cavity is favorable, as in the present case, endocrown restoration may be indicated to restore the biomechanics of the tooth [6].

In the present case, the loss of occlusal tooth structure was an indication for an onlay preparation, allowing thicker occlusal coverage with ceramic. Recently, a superior internal fit was observed in a study employing heat press manufacturing (VITA-PM9) compared with a CAD/CAM fabricated all-ceramic onlay [13]; both techniques provided clinically acceptable marginal and internal fit after luting. Additionally, the onlay cavity preparation was surrounded by enamel, which improved the durability of the adhesive system [14, 15]. Several factors affect the accuracy of the die, such as, impression technique, the elastic recovery of the material, and impression and die material [16]. These factors when controlled properly result in acceptable cement film thickness. Thus, no spacer was used on the die.

With the development of adhesive cementation systems, the need for macroretentive preparation for crowns has decreased [7]. These systems also balance the strength of the leucite glass ceramic crowns with the strength of a strong ceramic [17]. Hence, an endocrown composed of leucite-reinforced ceramic favors preservation of the tooth structure and is consistent with the goal of minimally invasive dentistry.

The endocrown ceramic restoration using the VITA-PM9 system is a feasible and conservative approach for mechanical and aesthetic restoration of nonvital posterior teeth.

Conflict of Interests

The authors declare that there is no conflict of interests regarding the publication of this paper.

Acknowledgment

The restoration was fabricated at Laboratório Futuro by Adriano Rafael Oliveira Santos, Belo Horizonte, MG, Brazil.

References

  1. A. Ploumaki, A. Bilkhair, T. Tuna, S. Stampf, and J. R. Strub, “Success rates of prosthetic restorations on endodontically treated teeth; a systematic review after 6 years,” Journal of Oral Rehabilitation, vol. 40, no. 8, pp. 618–630, 2013. View at: Publisher Site | Google Scholar
  2. G. Bateman, D. N. J. Ricketts, and W. P. Saunders, “Fibre-based post systems: a review,” British Dental Journal, vol. 195, no. 1, pp. 43–48, 2003. View at: Publisher Site | Google Scholar
  3. R. S. Schwartz and J. W. Robbins, “Post placement and restoration of endodontically treated teeth: a literature review,” Journal of Endodontics, vol. 30, no. 5, pp. 289–301, 2004. View at: Publisher Site | Google Scholar
  4. D. Dietschi, O. Duc, I. Krejci, and A. Sadan, “Biomechanical considerations for the restoration of endodontically treated teeth: a systematic review of the literature. Part II (Evaluation of fatigue behavior, interfaces, and in vivo studies),” Quintessence International, vol. 39, no. 2, pp. 117–129, 2008. View at: Google Scholar
  5. A. Bindl and W. H. Mörmann, “Clinical evaluation of adhesively placed Cerec endo-crowns after 2 years—preliminary results,” Journal of Adhesive Dentistry, vol. 1, no. 3, pp. 255–265, 1999. View at: Google Scholar
  6. M. Fages and B. Bennasar, “The endocrown: a different type of all-ceramic reconstruction for molars,” Journal of the Canadian Dental Association, vol. 79, article d140, 2013. View at: Google Scholar
  7. E. Lander and D. Dietschi, “Endocrowns: a clinical report,” Quintessence International, vol. 39, no. 2, pp. 99–106, 2008. View at: Google Scholar
  8. M. Kaiser, A. Wasserman, and J. R. Strub, “Long-term clinical results of VITA In-Ceram Classic: a systematic review,” Schweizer Monatsschrift für Zahnmedizin, vol. 116, no. 2, pp. 120–128, 2006. View at: Google Scholar
  9. A. Wassermann, M. Kaiser, and J. R. Strub, “Clinical long-term results of VITA In-Ceram Classic crowns and fixed partial dentures: a systematic literature review,” International Journal of Prosthodontics, vol. 19, no. 4, pp. 355–363, 2006. View at: Google Scholar
  10. S. Schultheis, J. R. Strub, T. A. Gerds, and P. C. Guess, “Monolithic and bi-layer CAD/CAM lithium-disilicate versus metal-ceramic fixed dental prostheses: comparison of fracture loads and failure modes after fatigue,” Clinical Oral Investigations, vol. 17, no. 5, pp. 1407–1413, 2013. View at: Publisher Site | Google Scholar
  11. Y. Goto, J. I. Nicholls, K. M. Phillips, and T. Junge, “Fatigue resistance of endodontically treated teeth restored with three dowel-and-core systems,” Journal of Prosthetic Dentistry, vol. 93, no. 1, pp. 45–50, 2005. View at: Publisher Site | Google Scholar
  12. M. C. Cagidiaco, C. Goracci, F. Garcia-Godoy, and M. Ferrari, “Clinical studies of fiber posts: a literature review,” International Journal of Prosthodontics, vol. 21, no. 4, pp. 328–336, 2008. View at: Google Scholar
  13. P. C. Guess, T. Vagkopoulou, Y. Zhang, M. Wolkewitz, and J. R. Strub, “Marginal and internal fit of heat pressed versus CAD/CAM fabricated all-ceramic onlays after exposure to thermo-mechanical fatigue,” Journal of Dentistry, vol. 42, no. 2, pp. 199–209, 2014. View at: Publisher Site | Google Scholar
  14. J. De Munck, K. Van Landuyt, M. Peumans et al., “A critical review of the durability of adhesion to tooth tissue: methods and results,” Journal of Dental Research, vol. 84, no. 2, pp. 118–132, 2005. View at: Publisher Site | Google Scholar
  15. M. Peumans, P. Kanumilli, J. De Munck, K. Van Landuyt, P. Lambrechts, and B. Van Meerbeek, “Clinical effectiveness of contemporary adhesives: a systematic review of current clinical trials,” Dental Materials, vol. 21, no. 9, pp. 864–881, 2005. View at: Publisher Site | Google Scholar
  16. E. B. Franco, L. F. da Cunha, F. S. Herrera, and A. R. Benetti, “Accuracy of single-step versus 2-step double-mix impression technique,” ISRN Dentistry, vol. 2011, Article ID 341546, 5 pages, 2011. View at: Publisher Site | Google Scholar
  17. A. Bindl, H. Lüthy, and W. H. Mörmann, “Strength and fracture pattern of monolithic CAD/CAM-generated posterior crowns,” Dental Materials, vol. 22, no. 1, pp. 29–36, 2006. View at: Publisher Site | Google Scholar

Copyright © 2015 Leonardo Fernandes da Cunha et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.


More related articles

2506 Views | 1096 Downloads | 3 Citations
 PDF  Download Citation  Citation
 Download other formatsMore
 Order printed copiesOrder

Related articles

We are committed to sharing findings related to COVID-19 as quickly and safely as possible. Any author submitting a COVID-19 paper should notify us at help@hindawi.com to ensure their research is fast-tracked and made available on a preprint server as soon as possible. We will be providing unlimited waivers of publication charges for accepted articles related to COVID-19. Sign up here as a reviewer to help fast-track new submissions.