Unusual Etiology and Diagnosis of Oroantral Communication due to Late Implant Failure

Figure 2

Ten years after implant placement. (a) Periapical radiograph, (b) clinical view, flap at site 25, and (c) cone-beam computed tomography image. Note the opacity of the left sinus.
(a)
(b)
(c)

We are committed to sharing findings related to COVID-19 as quickly as possible. We will be providing unlimited waivers of publication charges for accepted research articles as well as case reports and case series related to COVID-19. Review articles are excluded from this waiver policy. Sign up here as a reviewer to help fast-track new submissions.