New Implant Design with Midcrestal and Apical Wing Thread for Increased Implant Stability in Single Postextraction Maxillary Implant

Academic Editor: Giuseppe Alessandro Scardina
Received11 Jun 2019
Revised06 Aug 2019
Accepted14 Aug 2019
Published05 Sep 2019

Abstract

Background. The immediate placement of a dental implant could represent an option treatment for the rehabilitation of a postextractive missing tooth socket to replace compromised or untreatable teeth, with the advantage of single-session surgery. In this way, the anatomy of the alveolar bone defect, the preservation of the buccal cortical bone, and the primary stability of the fixture represent the critical factors that consent a precise implant placement. Objective. This case report describes a novel fixture design for postextractive alveolar socket immediate implant. Methods. Two patients (25 and 31 years old) were treated for postextractive dental implant placement to replace both central upper incisor teeth with four implants. The residual bone implant gap was not filled with graft or bone substitute. The restoration was provided following a standard loading protocol by a cement-sealed prosthetic abutment. Results. Clinically, all implants positioned showed an excellent insertion torque. No postoperative complications were reported. At 6 months of healing, the buccal cortical bone and the implant stability were present and well maintained. Conclusion. The evidence of this study allows us to underline the possible advantages of this new fixture design for postextractive implant technique.

1. Introduction

Nowadays, dental implants are recognized as a reliable treatment option for replacing missing teeth for periodontal defects, endodontic problems, trauma, fracture, and bone tissue atrophy is often present, which is more marked in a horizontal direction [1, 2].

The presence of vertical and horizontal lack of bone tissue represents an indispensable condition in order to reach stable implant-prosthetic rehabilitation over time [35]. Primary implant stability is a key factor that influences the success rate of these implants and determines the timing of prosthetic loading [6]. Many factors influence implant stability such as quality and quantity [7], shape, size, length, and the variety of surfaces [8, 9]. Primary implant stability is also important in case of immediate implant placement into fresh extraction sockets [10].

In this clinical situation, there is a bone defect and primary implant stability is very difficult to achieve. The surgical method allows reaching aspired aesthetical results, but a certain failure percentage has been reported [11, 12] due to different causes such as the presence of bacteria, absence of good primary stability, and lack of adequate bone support. Nowadays, the most used surgical protocol constitutes removing the causal element and waiting 2 months or more in order to reach socket healing. In a case of inadequate bone tissue where regenerative surgery is used to rehabilitate function and aesthetics [12, 13], it is necessary to wait an additional healing period.

In case of immediate postextractive implants for increasing the implant stability, a new implant geometry was introduced, aimed specifically at enabling better initial and long-term stability. This implant has a specially designed expanded diameter and a midcrestal and apical “wing” thread, which provides added bone contact for a higher insertion torque for primary stability.

The aim of this case report was to evaluate this novel implant design in two patients with immediate postextractive implant in an aesthetic area.

2. Case Report

A total of two patients, a 25-year-old male and a 31-year-old female, who required extraction of both central upper incisor teeth because of caries were selected. Neither patient presented chronicle or acute diseases that could influence osseointegration. The patients were nonsmokers with a good and correct domiciliary oral hygiene. A three-dimensional radiographic tomography scan (CBCT) (Vatech Ipax 3D PCH-6500, Fort Lee, NJ, USA) was performed before and after 6 months of implant placement. Two grams of amoxicillin was prescribed to both patients 2 hours before surgery. Chlorhexidine digluconate mouthwashes (Curaden Healthcare S.p.A., Saronno, Italy) were also recommended for at least 7 days after every meal or beverage, avoiding rinsing by water.

The extraction of the teeth was executed without flap in order to allow postextractive implant placement (Figures 1 and 2). To prepare the implant site, a 2 mm diameter bur was first used that was 15° palatally inclined and worked along the socket remaining after extraction; this inclination allows the palatal direction preserving greater quantity of vestibular bone tissue. It must be emphasized that the implant sites did not respect socket length completely, since they had to move apically in a palatal direction. Compared to the implant, the site has to have a smaller section (0.5 mm) in order to guarantee greater quantity of vestibular bone tissue and assure valid primary stability. The final bur length has to be equal to the inserting fixture, which was 12 mm in these two cases. The implant site was prepared with dedicated surgical cutters, as indicated by the manufacturer with a sequential cutter passage: pilot cutter 2 mm and 3.1 mm, 3.9 mm then 4.25 mm terminal cutter. To verify the height of the implant site preparation, a 2 mm diameter and 12 mm length measurer was inserted. The insertion of a 4.5 mm diameter and 12 mm length X-Space implant (Bone System® Implant System, Milano, Italy) completed the surgery (Figure 3). This dental implant has a rounded apex and two sharp and highly engaging threads, located close to each other to facilitate implant insertion.

The implants were placed with a mean insertion torque of measured with a manual torque wrench by the dentist and recorded for statistical analysis (GraphPad 6.0, Prism, San Diego, USA). No bone substitute was used for filling the implant gap. The implants were loaded with standard protocol, and the reverse torque was evaluated at 6 months after healing in the second phase surgery [14, 15].

3. Results

The four implant implants showed good radiologic osseointegration (Figure 4). The application of a 60 Ncm torque by a manual torque after 6 months of implant placement was not sufficient for detaching them from the bone. This confirms the good integration of the implants. A three-dimensional radiographic tomography scan (CBCT) (Vatech Ipax 3D PCH-6500, Fort Lee, NJ, USA) was performed before the procedure. The CBCT image after 6 months of implant placement showing the preserved buccal plate and the gap was filled by a new bone (Figure 4).

4. Discussion

The application of this new implant design in immediate postextractive socket guarantees a valid primary stability that is indispensable for following implant osseointegration. The use of the studied implant with an expanded diameter and midcrestal and apical “wing” thread, inserted by dynamometer ratchet pressure, determines preservation of the postextractive site and increases implant stability. Immediate implant placement into fresh extraction sockets is extensively used in clinical practice and is considered a predictable and acceptable procedure [16, 17]. In this report, the procedure for immediate implant placement with an expanded diameter thread in the midcrestal and apical area was conducted as planned and a favourable result was obtained, as shown by the initial postoperation images. Ever since the immediate implant placement procedure was developed, the maintenance of the buccal bony wall and implant stability has always been a major concern for implantologists.

5. Conclusion

After 6 months of clinical observation, this report demonstrates that the stability of immediately placed implants can be ensured by an expanded diameter thread in the midcrestal and apical area. However, due to the limitations associated with the use of only two case reports and four implants, further research is required to confirm it.

Conflicts of Interest

The authors declare that they have no conflicts of interest.

References

  1. C. E. Jansen and A. Weisgold, “Presurgical treatment planning for the anterior single-tooth implant restoration,” Compendium of Continuing Education in Dentistry, vol. 16, no. 8, 1995. View at: Google Scholar
  2. P. S. Wöhrle, “Single-tooth replacement in the aesthetic zone with immediate provisionalization: fourteen consecutive case reports,” Practical Periodontics and Aesthetic Dentistry, vol. 10, no. 9, pp. 1107–1114, 1998. View at: Google Scholar
  3. A. Scarano, A. Piattelli, G. Murmura, G. Iezzi, B. Assenza, and C. Mancino, “Delayed expansion of the atrophic mandible by ultrasonic surgery: a clinical and histologic case series,” The International Journal of Oral & Maxillofacial Implants, vol. 30, no. 1, pp. 144–149, 2015. View at: Publisher Site | Google Scholar
  4. A. Scarano, G. Murmura, G. Vantaggiato et al., “Delayed expansion of atrophic mandible (deam): a case report,” Oral & Implantology, vol. 10, no. 2, pp. 190–196, 2017. View at: Publisher Site | Google Scholar
  5. A. Scarano, F. Carinci, B. Assenza, M. Piattelli, G. Murmura, and A. Piattelli, “Vertical ridge augmentation of atrophic posterior mandible using an inlay technique with a xenograft without miniscrews and miniplates: case series,” Clinical Oral Implants Research, vol. 22, no. 10, pp. 1125–1130, 2011. View at: Publisher Site | Google Scholar
  6. L. Sennerby and N. Meredith, “Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications,” Periodontology 2000, vol. 47, no. 1, pp. 51–66, 2008. View at: Publisher Site | Google Scholar
  7. F. Javed and G. E. Romanos, “The role of primary stability for successful immediate loading of dental implants. A literature review,” Journal of Dentistry, vol. 38, no. 8, pp. 612–620, 2010. View at: Publisher Site | Google Scholar
  8. P. Cappare, G. Sannino, M. Minoli, P. Montemezzi, and F. Ferrini, “Conventional versus digital impressions for full arch screw-retained maxillary rehabilitations: a randomized clinical trial,” International Journal of Environmental Research and Public Health, vol. 16, no. 5, p. 829, 2019. View at: Publisher Site | Google Scholar
  9. P. Capparé, R. Vinci, D. A. di Stefano et al., “Correlation between initial BIC and the insertion torque/depth integral recorded with an instantaneous torque-measuring implant motor: an in vivo study,” Clinical Implant Dentistry and Related Research, vol. 17, Supplement 2, pp. e613–e620, 2015. View at: Publisher Site | Google Scholar
  10. A. Scarano, “Traditional postextractive implant site preparation compared with pre-extractive interradicular implant bed preparation in the mandibular molar region, using an ultrasonic device: a randomized pilot study,” The International Journal of Oral & Maxillofacial Implants, vol. 32, no. 3, pp. 655–660, 2017. View at: Publisher Site | Google Scholar
  11. A. Piattelli, A. Scarano, and M. Piattelli, “Microscopical aspects of failure in osseointegrated dental implants: a report of five cases,” Biomaterials, vol. 17, no. 12, pp. 1235–1241, 1996. View at: Publisher Site | Google Scholar
  12. L. Huys, “Replacement therapy and the immediate post-extraction dental implant,” Implant Dentistry, vol. 10, no. 2, pp. 93–102, 2001. View at: Publisher Site | Google Scholar
  13. D. P. Tarnow and R. N. Eskow, “Considerations for single-unit esthetic implant restorations,” Compendium of Continuing Education in Dentistry, vol. 16, no. 8, 1995. View at: Google Scholar
  14. N. Mall, B. Dhanasekar, and I. N. Aparna, “Validation of implant stability: a measure of implant permanence,” Indian Journal of Dental Research, vol. 22, no. 3, pp. 462–467, 2011. View at: Publisher Site | Google Scholar
  15. S. G. Simeone, M. Rios, and J. Simonpietri, ““Reverse torque of 30 Ncm applied to dental implants as test for osseointegration”-a human observational study,” International Journal of Implant Dentistry, vol. 2, no. 1, p. 26, 2016. View at: Publisher Site | Google Scholar
  16. L. Tettamanti, C. Andrisani, M. A. Bassi, R. Vinci, J. Silvestre-Rangil, and A. Tagliabue, “Post extractive implant: evaluation of the critical aspects,” Oral & Implantology, vol. 10, no. 2, pp. 119–128, 2017. View at: Publisher Site | Google Scholar
  17. A. Barone, P. Toti, A. Quaranta, G. Derchi, and U. Covani, “The clinical outcomes of immediate versus delayed restoration procedures on immediate implants: a comparative cohort study for single-tooth replacement,” Clinical Implant Dentistry and Related Research, vol. 17, no. 6, pp. 1114–1126, 2015. View at: Publisher Site | Google Scholar

Copyright © 2019 Antonio Scarano et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.


More related articles

709 Views | 445 Downloads | 0 Citations
 PDF  Download Citation  Citation
 Download other formatsMore
 Order printed copiesOrder

Related articles

We are committed to sharing findings related to COVID-19 as quickly and safely as possible. Any author submitting a COVID-19 paper should notify us at help@hindawi.com to ensure their research is fast-tracked and made available on a preprint server as soon as possible. We will be providing unlimited waivers of publication charges for accepted articles related to COVID-19. Sign up here as a reviewer to help fast-track new submissions.