Case Report

Immediate Placement and Restoration of a New Tapered Implant System in the Aesthetic Region: A Report of Three Cases

Table 1

Clinical, radiographic, and patient-centred outcomes.

Mesial bone level change (mm) -Distal bone level change (mm) -Mean midbuccal gingiva level change (mm) to Mean pockets at (mm)Bleeding score at VAS-score patient satisfactionPESWES

Case 10.000.00+1.742.3158924837
Case 2+0.300.00+0.733.5256878867
Case 3+0.11+1.05+0.322.305391na5na8
Mean2.7155.790.06.07.04.57.3

before treatment; after definitive crown placement; after definitive crown placement; . Positive value indicates that bone level was increased towards the implant shoulder. Zero indicates bone depicted at or above the implant shoulder at both and . Positive value indicates an incisal displacement of the mid buccal zenith.