Table of Contents Author Guidelines Submit a Manuscript
Case Reports in Ophthalmological Medicine
Volume 2012, Article ID 852304, 2 pages
http://dx.doi.org/10.1155/2012/852304
Case Report

Pigmentation of the Cornea Secondary to Tinted Soft Contact Lens Wear

St. Paul's Eye Unit, Royal Liverpool University Hospital, Prescot Road, Liverpool, L7 8XP, UK

Received 22 November 2011; Accepted 4 January 2012

Academic Editor: S. Machida

Copyright © 2012 Natasha Spiteri et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

Purpose. To report a case of pigmented corneal iron lines following use of tinted soft contact lenses (CL). Methods. A retrospective case report. Results. A 16-year-old girl was referred with suspected CL-related keratopathy OU, having recently switched to tinted soft monthly disposable CLs (8.4/14.0 −3.00 OD, −3.25 OS Aquamarine SofLens Natural Colours, Bausch and Lomb, New York, USA). Both corneas exhibited symmetric superficial corneal pigmented iron lines, which gradually disappeared following discontinuation of CL wear. Conclusions. Pigmented corneal rings have been reported in normal ageing corneas, in certain pathological conditions, and in association with altered corneal topography following LASIK and orthokeratology. We suspect a poorly fitting CL resulted in localised tear pooling between the CL and cornea, and subsequent iron pigment deposition, similar to that seen with orthokeratology. Cosmetic CLs bought via the Internet can be used in an unsupervised manner, with possible impacts on visual function and potential complications.

1. Introduction

We report the case of a young female with apparent bilateral, symmetric pigmented iron lines on the cornea following the use of daily wear tinted soft monthly disposable CLs. Corneal iron lines have been reported in association with altered corneal topography and tear pooling in orthokeratology; however, to our knowledge, they have not been reported in association with tinted soft monthly CLs to date.

2. Methods

A retrospective case report format is used.

3. Results

A 16-year-old girl was referred with a history of a suspected CL-related keratopathy in both eyes, shortly after having switched to tinted soft monthly disposable CLs (8.4/14.0 −3.00 OD, −3.25 OS Aquamarine SofLens Natural Colours, Bausch and Lomb, New York).

Best corrected visual acuities (BCVA) were 6/9 OD and 6/5 OS. Both corneas exhibited symmetric superficial corneal pigmented iron lines (Figure 1). No other ocular surface abnormality was present. Following discontinuation of CL wear the pigmented lines disappeared over the subsequent three months and BCVA improved to 6/4 OU.

852304.fig.001
Figure 1: Line of corneal pigmentation (arrowheads).

4. Discussion

Pigmented corneal rings have been reported in normal ageing corneas Hudson-Stahli lines and also in certain pathological conditions such as the Fleischer ring in keratoconus [1]. Corneal iron lines have also been associated with altered corneal topography and tear pooling following procedures such as LASIK [2] and orthokeratology [3].

Tinted CLs have been reported to induce several morphological and physiological changes in the cornea as well as having a negative impact on visual function. Previously noted morphological changes include a distinct ring-shaped pattern of irregular astigmatism with concentric areas of relative steepening and flattening, coined “the annular tinted contact lens syndrome.” These changes were rapidly reversible on discontinuing tinted lens use [4].

We suspect that in our case, a poorly fitting CL resulted in a localised pooling of tears between the CL and the corneal surface and subsequent deposition of iron pigment lines similar to that seen with orthokeratology.

In this case, the CLs were purchased over the Internet, and were being used in an unsupervised manner. This may often be the case, especially where users are buying plano-tinted CLs purely for cosmetic use via the Internet, and not from a CL specialist. This may present increasing problems to ophthalmic practitioners, in view of the possible impacts on visual function and potential complications associated with these lenses.

References

  1. J. D. Gass, “The iron lines of the superficial cornea. Hudson-Stahli line. Stocker’s line and Fleischer’s ring,” Archives of Ophthalmology, vol. 71, pp. 348–358, 1964. View at Google Scholar
  2. A. Ozdamar, C. Aras, C. Ustundag, H. Bahcecioglu, and S. Ozkan, “Corneal iron ring associated with iatrogenic keratectasia after myopic laser in situ keratomileusis,” Journal of Cataract and Refractive Surgery, vol. 26, no. 11, pp. 1684–1686, 2000. View at Publisher · View at Google Scholar · View at Scopus
  3. T. Hiraoka, A. Furuya, R. Wu, Y. Matsumoto et al., “Corneal iron ring associated with orthokeratology,” Journal of Cataract and Refractive Surgery, vol. 29, no. 3, pp. 624–626, 2000. View at Google Scholar
  4. F. A. Bucci, R. E. Evans, K. J. Moody, J. B. Tanner, R. C. Capozza, and S. D. Klyce, “The annular tinted contact lens syndrome,” CLAO Journal, vol. 23, no. 3, pp. 161–167, 1997. View at Google Scholar · View at Scopus