Case Report

A Novel Technique for Recurrent Tube Exposure Repair

Table 1

Patient characteristics and outcomes.

CaseGlaucoma typeTime to exposurePrior tube exposure repairPreop VAPostop VAPre IOPPost IOPPre # dropsPost # dropsFollow-up

1SI-OAG39 moConjunctiva oversewn20/200HM15114260 mo
2NVG1 moK/AMGHMLP17190151 mo

Abbreviations: SI-OAG=steroid-induced open angle glaucoma; NVG=neovascular glaucoma; Time to exposure=time from initial GDD implantation to first exposure of tube; K/AMG=corneal and amniotic membrane patch graft.