Case Report

Tracheoesophageal Fistula due to a Damaged Tracheal Stent

Figure 3

Esophagoscopy. (a) The esophageal orifice was visible on esophagoscopy. (b) Strangulation in the cervical esophagus was present. (c) Granulation tissue had developed. (d) A defect in the esophageal wall was present, and the tracheal tube was visible.
926387.fig.003a
(a)
926387.fig.003b
(b)
926387.fig.003c
(c)
926387.fig.003d