Case Report

Ventral Stabilization of a T2-T3 Vertebral Luxation via Median Sternotomy in a Dog

Figure 6

(a) Postoperative ventrodorsal radiographic projection of the cranial thoracic spine at the level of the spinal subluxation. Juxtaposed string of pearl plates are secured from the C7 to T4 vertebral bodies. The 8-hole plate on the dog’s left engages vertebral bodies C7, T2, T3, and T4. The 6-hole plate on the dog’s right side engages vertebral bodies C7, T1, and T3. Two wires are noted from the medial sternotomy closure superimposed over the 6-hole plate. (b) Postoperative lateral radiographic projection of the cranial thoracic spine at the level of the spinal subluxation. Screws are noted to engage vertebral bodies of C7-T2 cranial to the injury. Three screws engage vertebrae T3 and T4.
(a)
(b)