Accuracy of individual studies: chest ultrasound in characterization of pneumothorax in adults.

StudyYearParticipantsTPFPFNTNSensitivity (95% CI)Specificity (95% CI)
95%LowUp95%LowUp

Cattarossi2016492300261000.8521001000.868100
Raimondi2016422600161000.8681001000.794100
Corsini2018124802114800.4440.9751000.968100
Pooled21557021560.9660.8830.9961000.977100

TP, true positive; FP, false positive; FN, false negative; TN, true negative; 95% CI, 95% confidence interval.