Review Article

Accuracy of Ultrasound in Diagnosis of Pneumothorax: A Comparison between Neonates and Adults—A Systematic Review and Meta-Analysis

Table 5

Accuracy of individual studies: absence of lung sliding in characterization of pneumothorax.

StudyYearParticipantsTPFPFNTNSensitivity (95% CI)Specificity (95% CI)
95%LowUp95%LowUp

Raimondi2016422402160.9230.7490.9911000.794100
Liu20179030010500.7500.5880.8731000.929100
Wang Tang201438800301000.6311001000.884100
Kosiak201363202590.500.0680.9321000.939100
Pooled23364141550.8210.7170.8981000.976100

TP, true positive; FP, false positive; FN, false negative; TN, true negative; 95% CI, 95% confidence interval.