Author, year Design Country Kind of ICU No. of patients Endotracheal tube type Internal diameter of tracheal tube Cuff pressure PEEP VAP assessment Duration of follow-up Quality assessment Jaillette et al. 2017 [14 ] Multicenter, randomized, cross-over, open-label France Mixed ICU Tapered ( ), standard ( ). PVC tapered-cuffs (TaperGuard; Covidien, Athlone, Ireland); PVC standard cuffs (Hi-Lo; Covidien, Athlone, Ireland) 7.5 and 8 mm Tapered 29 (26–30) cmH2 O, conventional 28 (25–30)cmH2 O >5 cmH2 O Using clinical, radiographic, and microbiological criteria. Until 28 days or ICU discharge Good Mahmoodpoor et al., 2013, [16 ] Randomized, single-blind Iran Mixed ICU Tapered ( ), standard ( ). TaperGuard tubes (PU, cone-/taper-shaped cuffs with subglottic suction ports); SealGuard tubes (PU, cylindrical-/barrel-shaped cuffs with subglottic secretion suction ports). Male 8.0 to 8.5 mm, female 7.0 to 7.5 mm. Tapered (24.07 ± 0.48 cmH2 O), conventional (24.10 ± 0.49 cmH2 O) 5 cmH2 O VAP was defined based on clinical, radiological, and laboratory findings based on CPIS. Until ICU discharge Good Mahmoodpoor et al., 2017, [15 ] Randomized, single-blind Iran Surgical ICU Tapered ( ), conventional ( ). TaperGuard tubes; conventional high-volume low-pressure endotracheal tubes. Male 8.0 to 8.5 mm, female 7.0 to 7.5 mm. Tapered (23.7 ± 2.3 cmH2 O), conventional (27.0 ± 4.7 cmH2 O) 5 cmH2 O Suspected by clinical infection pulmonary score (CPIS) Until ICU discharge Good Monsel et al., 2016, [17 ] Randomized, single-blind France Surgical ICU Tapered ( ), standard ( ). TaperGuard (Covidien, Ireland); standard cuffs with high contour Brandt endotracheal tubes incorporating a polyvinyl chloride spherical-shaped cuff (Mallinckrodt Medical,USA) The endotracheal tube size was chosen according to professional guidelines. 25 cmH2 O Tapered 5.6 (5.0–6.3) cmH2 O, conventional 5.0 (5.0–6.0) cmH2 O VAP was confirmed when Johanson criteria were associated with a significant concentration of bacteria isolated from lower respiratory tract. Lengths of mechanical ventilation and ICU stay. Good Philippart et al., 2015, [13 ] Randomized, multicenter, open-lablel France and Tunisia Medical surgical ICUs Tapered ( ), standard ( ) TaperGuard (Covidien, Ireland); cylindrical (Hi-Lo; Covidien, Dublin, Ireland) The patients received tracheal intubation with a 7.5–8.0 mm diameter. The cuff was inflated to a pressure of 25–30 cmH2 O ≥5 cmH2 O VAP was confirmed when the quantitative culture was at least 104 cfu/ml in a bronchoalveolar lavage or 105 dfu/ml in a quantitative tracheal aspirate. Until ICU discharge Good