Research Article

A Follow-Up Study of Lung Function and Chest Computed Tomography at 6 Months after Discharge in Patients with Coronavirus Disease 2019

Table 3

Comparison of pulmonary function between moderate and severe patient groups.

Moderate (n = 31)Severe (n = 22)t

TLC (%)97.8 ± 11.899.5 ± 11.7−0.5250.602
FVC (%)97.8 ± 11.899.5 ± 11.7−0.5250.602
FEV1 (%)96.6 ± 13.598.5 ± 11.5−0.5470.587
FEV1/VCMAX%102.6 ± 6.7103.2 ± 4.1−0.4350.665
FEF50 (%)89.1 ± 22.990.2 ± 19.2−1.770.86
FEF75 (%)70.9 ± 29.873.9 ± 21.3−0.4050.687
MMEF (%)82.1 ± 23.583.7 ± 17.0−0.2550.800
DLCO-SB (%)83.7 ± 11.285.1 ± 12.1−0.4250.673

DLCO-SB, diffusing capacity for carbon monoxide corrected for hemoglobin; FEF50, maximum expiratory flow at 50% FVC; FEF75, maximum expiratory flow at 75% FVC; FEV1, forced expiratory volume in one second; FVC, forced vital capacity; MMEF, maximum midexpiratory flow; TLC, total lung capacity; VCMAX%, maximum vital capacity percentage.