Research Article

Dyssynchrony Assessment with Tissue Doppler Imaging and Regional Volumetric Analysis by 3D Echocardiography Do Not Predict Long-Term Response to Cardiac Resynchronization Therapy

Table 4

Assessment of QRS duration and echocardiographic dyssynchrony parameters validated in other trials to predict long-term clinical and echocardiographic response.

Pre-CRT dyssynchrony
parameters
Total
( 𝑛 = 3 3 )
Clinical responders
( 𝑛 = 2 4 )
P-valueEchocardiographic responders
( 𝑛 = 1 9 )
P-value

QRS (ms)
<150960.660.7
≥150241813

TDI septal-lateral delay (ms)
<6520170.1130.2
≥651386

TDI (Tf-Ts) 12 LV segments (ms)
<32650.540.6
≥32271915

TDI (Tf-Ts) 6 basal LV segments (ms)
<831070.870.5
≥83231712

CRT: cardiac resynchronization therapy, LV: left ventricle, TDI: tissue Doppler imaging, Tf-Ts: difference in time to peak systolic velocity between the fastest and slowest LV segments.