Patients’ characteristics according to molecular study results.

Patient characteristicsNo variant ()Variant-positive () value

Age at dx, years (mean ± SD)40 ± 1142 ± 140.633
Age at ICD implantation, years (mean ± SD)50 ± 1251 ± 130.872
Male, (%)9 (60)3 (50)1.000
Familial cases, (%)6 (40)3 (50)1.000
Family history, (%)
 Sudden cardiac death1 (7)2 (33)0.184
Previous hospitalizations, (%)9 (64)4 (67)1.000
 Heart failure-related8 (57)2 (33)0.628
 Arrhythmic causes4 (29)3 (50)0.613
NYHA, (%)
 >I10 (67)5 (83)0.802
ECG data, (%)
 LBBB7 (47)3 (50)1.000
 Atrial fibrillation3 (20)1 (17)1.000
 NSVT4 (36)2 (33)1.000
 PVC5 (33)0 (0)0.262
Echocardiogram data
 LVEDD (mm) (mean ± SD)65 ± 763 ± 60.503
 LVEF (%) (mean ± SD)24 ± 834 ± 70.024
 RV impairment, (%)4 (31)3 (50)0.617

ICD: implantable cardioverter defibrillator; LBBB: left bundle branch block; LVEDD: left ventricular end-diastolic diameter; LVEF: left ventricular ejection fraction; NSVT: nonsustained ventricular tachycardia; RV: right ventricle; SD: standard deviation.