Research Article

Left Ventricular End Diastolic Volume and Ejection Fraction Calculation: Correlation between Three Echocardiographic Methods

Figure 5

Bland–Altman plots for the comparisons between (a) EDV_SB and EDV_3DE, (b) EDV_SB and EDV_STE, and (c) EDV_3DE and EDV_STE. Bias: 14.19 ml (95% CI 12.38–16.00); bias: 3.49 ml (95% CI 2.23–4.75); and Bias: 10.58 ml (95% CI -12.46 to -8.71), respectively.
(a)
(b)
(c)