Abstract

Background. Little research has been conducted to explore the postoperative outcomes of obese patients after transfemoral transcatheter aortic valve replacement (TF-TAVR). Objective. We investigated the influence of body mass index (BMI) on 1-year outcomes after TF-TAVR. Methods. We included retrospectively 1609 high- and intermediate-risk TAVR patients (mean EuroSCORE II 21 ± 11) operated under general anesthesia between March 2014 and March 2018 in central hospital, Bad Berka, Germany. We stratified the patients according to BMI. Results. Our demographic data analysis showed 41% of patients were male and the mean age was 78 (range, 61–92 years). According to the WHO classification, 33% patients had normal weight, 42% were defined as overweight, and 22% were obese. Obese patients showed statistically significant difference in their clinical parameters as having higher incidence of hypertension, diabetes mellitus, pulmonary hypertension, and chronic obstructive pulmonary disease; on the contrary, obese patients were found to be younger than others. We found no differences in valve types and sizes among the different BMI categories. Our mortality rate during the 1-year follow-up period was 17.8% (287 patients). Mortality was significantly higher in patients with BMI < 25 kg/m2 (1 year mortality 149 patients 28.2% in patients with BMI < 25 kg/m2 vs. 138 patients 12.6% in patients with BMI ≥ 25 kg/m2; ). Even after considering the confounding risk factors, BMI ≥ 25 kg/m2 was independently associated with reduced 1 year mortality (odds ratio (OR): 0.36, 95% confidence interval (CI): 0.21–0.6; ) in multivariate logistic regression analysis. The rate of vascular complication was higher in patients with BMI ≥ 25 kg/m2. However, the rate of blood transfusion was higher in patients with BMI < 25 kg/m2. All other serious complications occurred with equal distribution in both groups. Conclusion. In our single-center study, BMI ≥ 25 kg/m2 was independently associated with lower 1 year mortality after TF-TAVR.

1. Introduction

Obesity is considered to be a morbidity- and mortality-dependent cardiovascular factor [1]. However, this clinical factor is still under investigation in the literature in the domain of transcatheter aortic valve replacement (TAVR). Nevertheless, several studies expressed obese patients as having better outcomes when compared with nonobese patients in aortic valve replacement procedures [2, 3] and in percutaneous coronary intervention [4]. Tokarek et al. showed that increased BMI was independently associated with 1-year survival benefit after TAVR. However, there was no difference between the groups in terms of 30-day all-cause mortality [5].

As for the progressively increasing population and awareness to medical consequences, it would be logical to expect greater number of obese patients with aortic valve stenosis referred for TAVR. In this study, we evaluated how influential is the body mass index (BMI) on TAVR outcomes concerning procedure-related complications and mortality.

1.1. Study Population and Data Collection
1.1.1. Methods

(1) Study Design and Follow-Up. In this study, we retrospectively collected data of TAVR patients in our institute (Zentralklinik Bad Berka, Germany) in the period between March 2014 and March 2018. All patients signed routinely an informed consent preoperatively. Clinical, echocardiographic, and hemodynamic criteria were our diagnostic tools. Computerised tomography was our preparatory tool. Eligibility for TAVR was determined by our heart team. We collected 1609 patients in this period who underwent transfemoral TAVR. After hospital discharge, all patients were subjected to follow-up schedule at 3 months and 1 year. Mortality data were collected by contacting the patients and the referring physicians.

(2) TAVR Procedure. TAVR was performed under general anesthesia. Three types of aortic valve prostheses were used: the Evolut aortic valve prosthesis (Medtronic, Inc., Minneapolis, MN) (23, 26, 29, or 34 mm), the Edwards SAPIEN 3 prosthesis (Edwards Lifesciences Corp, Irvine, CA) (23, 26, and 29 mm), and the Symetis aortic valve prosthesis (Boston Scientific) (small, medium, and large). Two senior TAVR operators (a cardiac surgeon and an interventional cardiologist) were in charge of the whole procedure. Valve type and size were decided preoperatively according to CT and echocardiography. All intraoperative and postoperative special findings or complications were always recorded and documented.

(3) End Points. Periprocedural complications and mortality rates were evaluated according to VARC-2 definitions [6]. End points of the study were all-cause mortality at 1 year, major and life-threatening bleeding complications, major vascular complications, blood transfusions, cerebrovascular events, and need for permanent pacemakers following the procedure.

(4) BMI (Body Mass Index). This parameter was obtained from patients’ files by dividing the weight in kilograms by the square of the height in meters. We classified the patients into three groups: normal weight, BMI from 18.5 to 24.9 kg/m2; overweight, BMI from 25.0 to 29.9 kg/m2; and obese, BMI ≥ 30 kg/m2. In our cohort, only 1% of the patients were classified as underweight and being statistically noninfluential. This group was excluded from our study.

Before 01/2018, all TAVR patients were treated postoperatively with dual antiplatelet therapy (aspirin and clopidogrel) for 6 weeks and then monotherapy lifelong. Since 01/2018, all TAVI patients were treated postoperatively with monotherapy either aspirin or clopidogrel in the absence of indication to anticoagulation or anticoagulants.

(5) Statistical Analysis. All data were displayed as mean (standard deviation) for continuous variables and as the number (percentage) of patients in each group for categorical variables. Student’s t-test or the analysis of variance test was used to evaluate the statistical significance between continuous variables, whereas the χ2 test was used in case of categorical variables, respectively. Odds ratios were calculated with a confidence interval of 95%. The analysis was done for BMI as continuous as well as categorical variables (BMI < or 25 kg/m2). Furthermore, multivariate analysis is performed to explore the association between BMI ≥ 25 kg/m2 and 1 year mortality. All of the analyses were considered significant at a 2-tailed value of <0.05. All analyses were done using SPSS statistical software (IBM Corp. released 2013, IBM SPSS Statistics for Windows, version 22.0, Armonk, NY).

2. Results

Our total study cohort included 1609 patients (41% males) with a mean age of 78 (range, 61–92 years). Our demographic data analysis showed that the mean logistic EuroSCORE of the study patients was 21%, 88% of patients suffering from hypertension, 19% from COPD, 12% from PH, 57% from carotid stenosis, and 34% from diabetes. 28% of patients were classified as New York Heart Association class IV. Edwards SAPIEN 3 was implanted in 60% of patients, while the Evolut prosthesis was used in 31% of patients and Symetis prosthesis in 9% of patients. The clinical characteristics of patients according to their BMI classification are presented in Table 1. According to the WHO classification, 1% of patients were defined as underweight, 33% had normal weight, 42% were defined as overweight, and 22% were obese. As shown in Table 1, the obese patients showed statistically significant difference in their clinical parameters as having higher incidence of hypertension, diabetes mellitus, pulmonary hypertension, and chronic obstructive pulmonary disease; on the contrary, obese patients were found to be younger than others and consequently have lower logistic EuroSCORE. We found no differences in valve types and sizes among the different BMI categories.

Our mortality rate during the 1-year follow-up period was 17.8% (287 patients). Mortality was significantly higher in patients with BMI < 25 kg/m2 (The 1-year mortality in patients with BMI < 25 kg/m2 was 28.2% (149 patients) vs 12.6% (138 patients) in patients with BMI ≥ 25 kg/m2; ), see Figure 1. Even after considering the confounding risk factors, BMI ≥ 25 kg/m2 was independently associated with reduced 1 year mortality (odds ratio (OR): 0.36, 95% confidence interval (CI): 0.21–0.6; ) in multivariate logistic regression analysis, as shown in Table 2 und Figure 2. The rate of vascular complication was lower in patients with BMI ≥ 25 kg/m2. However, the rate of blood transfusion was higher in patients with BMI < 25 kg/m2. All other serious complications occurred with equal distribution in both groups, as shown in Table 3.

3. Discussion

In this retrospective observational study, we targeted to focus on the influence of BMI on TAVR outcomes. The principle conclusion was patients with BMI ≥ 25 kg/m2 had lower long-term mortality rates and, on the other hand, higher rate of procedure-related complications. As reported by the Nutrition Council of the American Heart Association, obesity is considered a risk factor for cardiovascular morbidity and mortality [1]. Obesity rates are progressively rising due to the sedentary life style and still associated with higher morbidity and mortality [7, 8]. On the contrary, Batty et al. and Lancefield et al. reported a better survival rates among obese patients [9, 10].

TAVR is known to be indicated in high and intermediate surgical risk candidates for aortic valve replacement [11]. However, to our knowledge, the BMI is an absent parameter in logistic EuroSCORE, and consequently, its influence on the TAVR outcomes has not been directly investigated in detail. Van der Boon et al. showed that obesity was associated with a decrease in 30-day mortality, but had no effect on long-term outcomes [12]. This conclusion point differs from our results in the following aspects: our cohort group is bigger in comparison with his as they retrospectively investigated 944 patients vs 1609 patients in our study. However, on the contrary, they reported no increase in procedure-related complications among the obese group which is opposite to what we found out in our study. Despite an increase in our periprocedural complications, we found lower 1-year mortality in patients with BMI ≥ 25 kg/m2. We would explain this finding by the fact that overweight patients might have more metabolic reserves [13]. Another explanation might be the fact that we were introducing a new closure device in our institute during the phase where this study was conducted. Our results go on line with the recent analysis from the FRANCE2 (French Aortic National CoreValve and Edwards 2) registry, according to which, among the TAVR population, overweight and obesity were associated with improved 1-year survival [14]. BMI remained an independent predictor of improved survival in multivariate analysis. This might be explained by the fact that overweight and obese patients are usually intensively treated with optimum medical therapy for the associated risk factors and consequently contributing to better outcomes [13].

Blood transfusion was found to be less frequent in the obese cohort in our study group. Despite the fact that hemoglobin level was similar among all groups on admission and the increased number of procedure-related complications in the obese group, we would interpret this as those patients were seen as less frail and less fragile and hence blood transfusion in this group was restricted only to patients suffering from progressive anemia and active bleeding; therefore, overall, patients defined as obese were treated with blood transfusion less frequently. Several studies support our results [1517].

3.1. Study Limitations

The main limitation of this study is being a retrospective observational study and there may have residual confounders (as the indicators of central obesity, CT measurements of visceral fat, and medications) that we did not account for. Another limitation of the current study is that the clinical follow-up for more than one year was not available, which might decrease the influence of important predictors such as age on mortality.

4. Conclusion

In our single-center study, BMI ≥ 25 kg/m2 was independently associated with lower 1-year mortality after transfemoral TAVR.

Data Availability

The data used to support the findings of this study have not been made available because of the absence of hospital agreement.

Conflicts of Interest

The authors declare that they have no conflicts of interest.

Authors’ Contributions

Owais T and El Garhy M contributed equally to this work.