Research Article
Modeling the Smart Factory Manufacturing Products Characteristics: The Perspective of Energy Consumption
Table 1
Different types of load and their timings concerning.
| Categories | Charge on demand (won/kW) | The cost of energy is expressed in won per kilowatt-hour | Period of time | Summer (Jul 1∼Aug 31) | Spring/fall (Mar 1∼Jun 30/Sep 1∼Oct 31) | Winter (Nov 1∼Feb 28) |
| High voltage (A) | Option I | 5710 | Off-peak load | 45.80 | 45.80 | 49.30 | Mid-load | 87.30 | 59.30 | 85.90 | Peak-load | 147.00 | 77.60 | 120.70 | Option II | 6540 | Off-peak load | 41.60 | 41.60 | 45.20 | Mid-load | 83.20 | 55.20 | 81.70 | Peak-load | 142.90 | 73.50 | 116.60 | High voltage (B) | Option I | 5710 | Off-peak load | 44.40 | 44.40 | 47.90 | Mid-load | 84.80 | 57.70 | 83.30 | Peak-load | 141.80 | 75.40 | 116.70 | Option II | 6540 | Off-peak load | 40.20 | 40.20 | 43.70 | Mid-load | 80.60 | 53.50 | 79.10 | Peak-load | 137.70 | 71.30 | 112.60 |
|
|