Research Article

A Two-Stage Robust Optimization Method Based on the Expected Scenario for Islanded Microgrid Energy Management

Table 8

Rescheduling results for three typical scenarios at various values ().

Scenario AScenario BScenario C
Total cost ()Total curtailed power of loads (kW)Total curtailed power of renewable energy (kW)Total cost ()Total curtailed power of loads (kW)Total curtailed power of renewable energy (kW)Total cost ()Total curtailed power of loads (kW)Total curtailed power of renewable energy (kW)

0546.100103.10080.6
1546.100103.10080.6
2546.600103.1008.4
3548.400873.0671.20423.1100