Research Article

Bearing Fault Diagnosis of End-to-End Model Design Based on 1DCNN-GRU Network

Table 4

Performance of model w.r.t different dropout value.

DropoutConverge time (s)Training accuracyTesting accuracy

0.125.50.99810.9775
0.224.90.99810.9700
0.325.40.99560.9750
0.4250.99870.9825
0.525.40.99870.9850