Association of Auricular Reflective Points and Status of Type 2 Diabetes Mellitus: A Matched Case-Control Study
Table 3
Predictive power of various ear acupoints on the risk of DM.
Sensitivity (%)
Specificity (%)
Positive predictive value (%)
Negative predictive value (%)
Marks appearing around “P&G” region after pressing, (Rt)
0.7
100
100
50.2
Marks appearing around “P&G” region after pressing, (Lt)
0.7
100
100
50.2
Tenderness, (Rt) (P&G)
73.0
70.2
71.0
72.3
Tenderness, (Lt) (P&G)
55.3
68.1
63.4
60.4
Electrical conductivity, (Rt)
P&G
66.0
73.8
71.5
68.4
Endocrine
62.4
64.5
63.8
63.2
Kidney
58.9
70.9
66.9
63.3
Lower tragus
43.3
70.9
59.8
55.6
Heart
56.7
68.8
64.5
61.4
Liver
27.7
80.9
59.1
52.8
Eyes
55.3
61.7
59.1
58.0
Electrical conductivity, (Lt)
P&G
61.0
75.2
71.1
65.8
Endocrine
51.8
73.8
66.4
60.5
Kidney
47.5
70.9
62.0
57.5
Lower tragus
38.3
73.8
59.3
54.5
Heart
52.5
74.5
67.3
61.0
Liver
25.5
83.7
61.0
52.9
Eyes
45.4
69.5
59.8
56.0
Sensitivity (true positive) = number of true positives/number of true positives + number of false negatives. Specificity (true negative) = number of true negatives/number of true negatives + number of false positives. Positive predictive value = number of true positives/number of true positives + number of false positives. Negative predictive value = number of true negatives/number of true negatives + number of false negatives.