Research Article

A Novel Microspheres Formulation of Puerarin: Pharmacokinetics Study and In Vivo Pharmacodynamics Evaluations

Table 1

Precision and accuracy of the method for the determination of puerarin in rat plasma ().

Concentration (μg/mL)IntradayInterday
Precision RSD%Accuracy RE%Precision RSD%Accuracy RE%

1.063.60−3.545.05−4.47
5.35.79−5.454.36−4.38
26.51.152.721.322.78