Comparative Studies on Chemical Contents and Effect in Kidney-Yang Deficiency Rats of Salt-Processed Product and Wine-Processed Product of Cuscutae Semen
Table 1
Method validation of fifteen analytes in UPLC-MS quantitation.
Number
tR (min)
Analytes
Formula
Regression equation
r2
Linear range (ng/ml)
LOD (μg/mL)
LOQ (μg/mL)
Precision (n = 6)
Repeatability (n = 6)
Stability (0–24 h)
1
5.51
3-CQA
C16H18O9
y = 0.0775x − 2872.8378
0.9988
20341–244093
0.0014
0.0041
1.96
3.86
5.79
2
16.73
4-CQA
C16H18O9
y = 0.1345x − 4699.9042
0.9991
3872–46461
0.0028
0.0084
0.33
0.44
0.57
3
1.46
3,4-DiCQA
C25H23O12
y = 0.3181x − 65.9357
0.9990
206–2478
0.0112
0.0225
0.0019
0.0017
0.02
4
2.34
3,5-DiCQA
C25H23O12
y = 0.2140x − 56.4874
0.9997
462–7394
0.4436
1.3309
0.0037
0.013
0.06
5
2.93
4,5-DiCQA
C25H23O12
y = 0.1230x − 274.8306
0.9974
477–7636
0.4582
1.3745
0. 01
0.03
0.31
6
5.85
CA
C9H8O4
y = 0.0003x − 0.4863
0.9915
5–75
0.0026
0.0105
0.03
0.07
0.16
7
7.73
5-FQA
C10H10O4
y = 0.3482x − 18.5959
0.9998
206–2470
0.0001
0.0004
0.0019
0.0006
0.0072
8
4.04
p-Hydroxycinnamic acid
C9H8O3
y = 0.1221x − 345.2182
0.9921
488–7806
0.0004
0.0014
0.03
0.03
0.37
9
10.03
Hyperoside
C21H20O12
y = 0.0638x − 4194.4234
0.9991
6833–109333
0.0036
0.0109
—
—
—
10
13.29
Astragalin
C21H20O11
y = 0.1698x − 10717.3813
0.9995
2683–42933
0.0172
0.0687
0.13
0. 4
0.09
11
23.75
Quercetin
C15H10O7
y = 0.0035x − 69.1497
0.9989
202–2424
0.0006
0.0012
0.28
0.43
0.64
12
27.77
Kaempferol
C15H10O6
y = 0.2544x − 406.6164
0.9974
5684–68210
0.0008
0.0017
0.24
0.09
0.63
13
28.54
Isorhamnetin
C16H12O7
y = 0.0190x − 1032.1204
0.9967
1351–16210
8.76E − 05
0.0004
0.32
0.73
1.18
14
10.4
Isoquercitrin
C21H20O12
y = 0.0473x − 2285.4629
0.9990
2567–41067
0.0020
0.0082
1.26
0.50
1.29
15
16.12
Luteolin-7-O-glucoside
C21H20O11
y = 0.4190x − 2399.9345
0.9978
2196–26358
0.0004
0.0013
0.06
0.02
0.02
In the regression equation, x is the peak area, y the concentration of each analyte (ng/mL), and r the correlation coefficient. LOD, limit of detection (S/N = 3); LOQ, limit of quantification (S/N = 10). Precision, repeatability, and stability are shown in RSD (%).