Research Article

Damage Characteristics and Mechanism of a Strong Water Inrush Disaster at the Wangjialing Coal Mine, Shanxi Province, China

Table 1

Results of the groundwater quality analysis unit: mg⋅l−1/X%.

SourceThe inrush waterThe Ordovician waterThe P+C sandstone water in the roof of the No.2 coal seam
Sampling siteThe water pump outletNo.1 supply wellS5 hydrological hole

Sampling time2010.3.282010.3.312010.4.22009.3.112008.8.6
Total hardness101.1791.8873.81454.212.46
Ca2+23.45/4.8826.22/3.5420.58/4.48324.97/48.763.33/1.06
Mg2+10.35/3.556.41/2.235.44/1.95156.06/38.601.01/0.53
Na+495.00/0.70495.93/91.36489.18/92.8094.67/12.38355.40/92.28
K+6.60/89.76
Fe3+1.60/0.360.19/0.040.23/0.041.52/0.240.34/0.10
Total cation540.52/100532.20/100518.31/100577.30/100360.20/100
Cl69.51/8.0060.98/7.2850.33/6.19515.92/43.7552.86/9.48
SO42−204.42/17.33205.39/18.11195.92/17.78537.55/33.65159.70/21.14
HCO31110.01/74.101072.74/74.461015.83/72.61456.29/22.48580.09/60.44
F2.64/0.572.96/0.683.40/0.78
Total anion1386.66/1001340.99/1001285.89/1001512.17/100835.36/100
pH value7.627.918.357.448.3
Salinity131013502089.471195.56
Hydrochemical typeHCO3-NaHCO3-NaHCO3-NaCl·SO4-Ca·MgHCO3-Na