Research Article

CO2 Leakage-Induced Contamination in Shallow Potable Aquifer and Associated Health Risk Assessment

Table 6

Different parameters for sensitivity studies. Three groups except Case 1 (base case) are designed for sorption rate () (Cases 2–4), gaseous CO2 leakage rate () (Cases 5–7), and horizontal permeability () (Cases 8–10), respectively.

Case nameSorption rate 
()
CO2 leakage rate 
()
Horizontal permeability 
()

Case 1 (base case)100.050 kg/s m2

Case 2250.050 kg/s m2
Case 3500.050 kg/s m2
Case 41000.050 kg/s m2

Case 5500.020 kg/s m2
Case 6500.025 kg/s m2
Case 7500.030 kg/s m2

Case 8500.050 kg/s m2
Case 9500.050 kg/s m2
Case 10500.050 kg/s m2