Research Article

Laboratory Leaching Tests to Investigate Mobilisation and Recovery of Metals from Geothermal Reservoirs

Table 7

Concentration of the “at risk” elements in each leachate from the flow-through reaction.

ElementAgCoGaMoSbSrVWTotal ‘at risk’
SamplePPBPPBPPBPPBPPBPPBPPBPPBPPB

HTL322 + DI water 14.240.619.45844.570.19869.05
HTL322 + DI water 22.770.615.81660.150.07679.40
HTL322 + DI water 32.020.565.22489.790.05557.58
HTL322 + 0.1 M acetic acid0.818.691.66414.460.23515.76
HTL324 + DI_water0.090.283.818.75377.310.31.06401.59
HTL324 + 0.1 M acetic acid2837.002837.00
HTL321 + DI_water1526.001526.00
HTL321 + 0.1 M acetic acid1094.001094.00
HTL315 + 0.1 M acetic acid209.298.3810227.67
HTL319 + 0.1 M acetic acid909.292744095.154701104.45
HTLMix + 0.1 M acetic acid2094.967918.331033.30

: concentration was under the detection limit.