Calculation results for circulation depth of geothermal water in the study area (temperature in °C and depth in km).

Sample IDEmerging temperatureReservoir temperature (C2)-Circulation depth

TS-1531261054.50
TS-245.51421215.19
TS-3451321114.76
TS-450.11481275.44
TS-560.21261054.50
TW-142.11441235.27
TW-248.41231024.38
TW-355.81251044.46
TW-450.21361154.93
TW-5501251044.46
TW-665108873.74
TW-760106853.65