Research Article

Development and Application of Fluid-Solid Coupling Similar Materials in Discharge Test of Old Goaf Water

Table 3

Tensile strength values of some test blocks.

Group numberCompressive strength (MPa)Tensile strength (MPa)

010.200.0200.11
020.440.0450.10
030.680.0670.098
040.920.0840.091
051.160.1260.108