Research Article
Lessons from the Case History of a Massive Landslide Dam
Table 1
Test parameters of the field electrical resistivity surveys at the Hattian Bala landslide dam.
| Survey location | Length of survey line (m) | No. of sequences | No. of data points | Maximum investigation depth (m) | Initial electrode spacing (m) | Electrode array |
| Phase 1 (November/December 2006) | Longitudinal | 894 | 59 | 3675 | 155 | 6 | Wenner alpha | Transverse at 22 m | 114 | 6 | 57 | 20 | Transverse at 124 m | 150 | 8 | 100 | 26 | Transverse at 237 m | 162 | 9 | 117 | 28 | Transverse at 574 m | 90 | 5 | 35 | 16 | Phase 2 (February/March 2007) | Longitudinal | 894 | 59 | 3675 | 155 | 6 | Wenner alpha | Transverse at 1114 m | 234 | 26 | 1001 | 41 | 3 |
|
|