Research Article

Effect of Gas Adsorption on the Application of the Pulse-Decay Technique

Table 2

Permeability measurement results under different conditions in the experiment.

Pore pressure (MPa)Pulse pressure (kPa)HeliumCarbon dioxide
Slope (μD) (Jones, 1997)Slope (μD) (Jones, 1997) (μD) (Cui et al., 2009)

140-0.00110.98435.86-0.04410.9843185.5432.1
60-0.00110.99235.81-0.03950.9936163.52379.13
80-0.00110.99515.77-0.03750.9953154.02356.85
100-0.00110.99735.72-0.03490.9974141.13323.91
240-0.00170.97384.65-0.04610.951997.4164.71
60-0.00180.98854.88-0.04070.991385.66144.02
80-0.00180.992534.86-0.0380.997679.66133.34
100-0.00180.995034.84-0.03540.994673.93123.02
340-0.0020.98193.68-0.03070.982944.4662.49
60-0.0020.99073.67-0.02890.995841.7458.4
80-0.0020.99353.66-0.02640.995737.8553.34
100-0.0020.99693.64-0.02440.997934.9849.01
440-0.00250.97773.47-0.01990.989620.3927.84
60-0.00260.99043.6-0.01750.988617.924.25
80-0.00260.99453.6-0.01620.997316.5122.37
100-0.00260.99673.58-0.0150.996415.2920.85