Research Article
Effect of Gas Adsorption on the Application of the Pulse-Decay Technique
Table 2
Permeability measurement results under different conditions in the experiment.
| Pore pressure (MPa) | Pulse pressure (kPa) | Helium | Carbon dioxide | Slope | | (μD) (Jones, 1997) | Slope | | (μD) (Jones, 1997) | (μD) (Cui et al., 2009) |
| 1 | 40 | -0.0011 | 0.9843 | 5.86 | -0.0441 | 0.9843 | 185.5 | 432.1 | 60 | -0.0011 | 0.9923 | 5.81 | -0.0395 | 0.9936 | 163.52 | 379.13 | 80 | -0.0011 | 0.9951 | 5.77 | -0.0375 | 0.9953 | 154.02 | 356.85 | 100 | -0.0011 | 0.9973 | 5.72 | -0.0349 | 0.9974 | 141.13 | 323.91 | 2 | 40 | -0.0017 | 0.9738 | 4.65 | -0.0461 | 0.9519 | 97.4 | 164.71 | 60 | -0.0018 | 0.9885 | 4.88 | -0.0407 | 0.9913 | 85.66 | 144.02 | 80 | -0.0018 | 0.99253 | 4.86 | -0.038 | 0.9976 | 79.66 | 133.34 | 100 | -0.0018 | 0.99503 | 4.84 | -0.0354 | 0.9946 | 73.93 | 123.02 | 3 | 40 | -0.002 | 0.9819 | 3.68 | -0.0307 | 0.9829 | 44.46 | 62.49 | 60 | -0.002 | 0.9907 | 3.67 | -0.0289 | 0.9958 | 41.74 | 58.4 | 80 | -0.002 | 0.9935 | 3.66 | -0.0264 | 0.9957 | 37.85 | 53.34 | 100 | -0.002 | 0.9969 | 3.64 | -0.0244 | 0.9979 | 34.98 | 49.01 | 4 | 40 | -0.0025 | 0.9777 | 3.47 | -0.0199 | 0.9896 | 20.39 | 27.84 | 60 | -0.0026 | 0.9904 | 3.6 | -0.0175 | 0.9886 | 17.9 | 24.25 | 80 | -0.0026 | 0.9945 | 3.6 | -0.0162 | 0.9973 | 16.51 | 22.37 | 100 | -0.0026 | 0.9967 | 3.58 | -0.015 | 0.9964 | 15.29 | 20.85 |
|
|