Research Article

Calculation Method for Inflow Performance Relationship in Sucker Rod Pump Wells Based on Real-Time Monitoring Dynamometer Card

Table 1

Calculation results.

NumberDynamometer cardIdentification resultsBottom hole flowing pressure (MPa)Fluid production (m3/d)
MeasuredCalculatedErrorMeasuredCalculatedError

1Normal8.28.53.66%29.129.61.72%
2Normal7.88.02.56%37.635.36.12%
3Abnormal7.143.2
4Normal6.66.83.03%46.547.31.72%
5Normal5.65.43.57%60.158.92.00%
6Normal4.04.25.00%65.867.11.98%
7Normal2.92.83.45%76.174.81.71%
8Normal1.41.57.14%78.780.42.16%
Average4.06%2.49%