Research Article

Study on Storage Conditions and Suitability Zoning of Shallow Floor Energy in Nanchang City

Table 4

Evaluation table of factors affecting the suitability of the ground source heat pump.

Element indicatorsGrading levelAssignment of the value

Aquifer effluent capacity (m3/d)<101
10~1003
100~10005
1000~50007
≥50009

Effective aquifer thickness (m)<101
10~203
20~405
40~607
≥609

Single-well recharge capacity of the aquifer (m3/d)<501
50~5003
500~10005
1000~20007
≥20009

Groundwater depth (m)<5, 100~2001
5~10, 80~1003
10~15, 50~805
15~20, 30~507
20~309

Permeability coefficient of formation (m/d)<51
5~103
10~205
20~507
≥509

Overexploitation of groundwaterGroundwater volume is abundant9
The groundwater volume is average5
Overdraft1

Underground water qualityClass I water9
Class II water7
Class III water5
Class IV water3
Class V water1

Groundwater scale degreeVery few9
Less often7
More than that5
A lot of it1