Research Article

Study on Autogenous Heat Technology of Offshore Oilfield: Experiment Research, Process Design, and Application

Table 2

Experimental data of heat generation in autogenic heat system.

Concentration (mol/L)Peak temperature (°C)Temperature range (°C)Experiment conditions

0.5634100 mL 1.0 mol/L NaNO2 solution+100 mL 1.0 mol/L NH4Cl solution
1.07919100 mL 2.0 mol/L NaNO2 solution+100 mL 2.0 mol/L NH4Cl solution
1.512767100 mL 3.0 mol/L NaNO2 solution+100 mL 3.0 mol/L NH4Cl solution
2.014282100 mL 4.0 mol/L NaNO2 solution+100 mL 4.0 mol/L NH4Cl solution
2.515797100 mL 5.0 mol/L NaNO2 solution+100 mL 5.0 mol/L NH4Cl solution
3.0178118100 mL 6.0 mol/L NaNO2 solution+100 mL 6.0 mol/L NH4Cl solution

Note: catalyst concentration: 0.3%; base brine: 60°C.